Don't miss your chance to get «Alaska» air heater at the most favourable price. 10% discount for all products and free delivery!
4 MAIN REASONS TO ORDER «ALASKA» AIR HEATERS
Heater’s service life when properly used
Real fuel savings
Output-Input Ratio of a heater
Air heater performance on one fuelling
CHOOSE FOR YOUR HOME OR COUNRTY HOUSE
Heated area volume limit, m3 | 100 |
Length, mm | 665 |
Width, mm | 500 |
Height, mm | 660 |
Weight, kg | 70 |
Max caloricity, kW, not less | 7 |
Normal heat release, kW | 3,0 |
Perfoemance efficiency not more, % | 90 |
Burner section volume, dm3 | 40 |
Combuster gate diameter, mm | 270 |
Flue system diameter, mm | 120 |
Flue system height, m | 5 |
Heated area volume limit, m3 | 100 |
Length, mm | 665 |
Width, mm | 500 |
Height, mm | 660 |
Weight, kg | 70 |
Max caloricity, kW, not less | 7 |
Normal heat release, kW | 3,0 |
Perfoemance efficiency not more, % | 90 |
Burner section volume, dm3 | 40 |
Combuster gate diameter, mm | 270 |
Flue system diameter, mm | 120 |
Flue system height, m | 5 |
Heated area volume limit, m3 | 200 |
Length, mm | 800 |
Width, mm | 570 |
Height, mm | 790 |
Weight, kg | 105 |
Max caloricity, kW, not less | 12 |
Normal heat release, kW | 6,5 |
Perfoemance efficiency not more, % | 90 |
Burner section volume, dm3 | 70 |
Combuster gate diameter, mm | 270 |
Flue system diameter, mm | 120 |
Flue system height, m | 7 |
Heated area volume limit, m3 | 400 |
Length, mm | 970 |
Width, mm | 600 |
Height, mm | 830 |
Weight, kg | 135 |
Max caloricity, kW, not less | 17 |
Normal heat release, kW | 7,5 |
Perfoemance efficiency not more, % | 90 |
Burner section volume, dm3 | 95 |
Combuster gate diameter, mm | 270 |
Flue system diameter, mm | 150 |
Flue system height, m | 7 |
Heated area volume limit, m3 | 600 |
Length, mm | 1125 |
Width, mm | 650 |
Height, mm | 880 |
Weight, kg | 160 |
Max caloricity, kW, not less | 25 |
Normal heat release, kW | 11,0 |
Perfoemance efficiency not more, % | 90 |
Burner section volume, dm3 | 135 |
Combuster gate diameter, mm | 270 |
Flue system diameter, mm | 150 |
Flue system height, m | 7 |
Heated area volume limit, m3 | 900 |
Length, mm | 1300 |
Width, mm | 700 |
Height, mm | 915 |
Weight, kg | 210 |
Max caloricity, kW, not less | 32 |
Normal heat release, kW | 13,5 |
Perfoemance efficiency not more, % | 90 |
Burner section volume, dm3 | 180 |
Combuster gate diameter, mm | 320 |
Flue system diameter, mm | 180 |
Flue system height, m | 7 |
Heated area volume limit, m3 | 1200 |
Length, mm | 1445 |
Width, mm | 730 |
Height, mm | 970 |
Weight, kg | 245 |
Max caloricity, kW, not less | 42 |
Normal heat release, kW | 17,0 |
Perfoemance efficiency not more, % | 90 |
Burner section volume, dm3 | 225 |
Combuster gate diameter, mm | 320 |
Flue system diameter, mm | 180 |
Flue system height, m | 7 |
WITH COOKING SURFACE
Heated area volume limit, m3 | 100 |
Height, mm, not more | 600 |
Width, mm, not more | 500 |
Length, mm, not more | 665 |
Weight, kg, not more | 75 |
Heat production limit, kW, not less |
7 |
Normal heat release, kW, +-15% |
3,0 |
Performance efficiency limit, %, not less | 75 |
Burner section volume, dm3 | 40 |
Combuster gate diameter, mm (+-3%) | 270 |
Flue system diameter, mm | 120 |
Flue system height, m, not less | 5 |
Wooden logs length, mm, not more |
380 |
Heated area volume limit, m3 | 200 |
Height, mm, not more | 720 |
Width, mm, not more | 570 |
Length, mm, not more | 800 |
Weight, kg, not more | 115 |
Heat production limit, kW, not less |
12 |
Normal heat release, kW, +-15% |
6,5 |
Performance efficiency limit, %, not less | 75 |
Burner section volume, dm3 | 70 |
Combuster gate diameter, mm (+-3%) | 270 |
Flue system diameter, mm | 120 |
Flue system height, m, not less | 7 |
Wooden logs length, mm, not more |
500 |
Heated area volume limit, m3 | 400 |
Height, mm, not more | 745 |
Width, mm, not more | 600 |
Length, mm, not more | 970 |
Weight, kg, not more | 150 |
Heat production limit, kW, not less |
17 |
Normal heat release, kW, +-15% |
7,5 |
Performance efficiency limit, %, not less | 75 |
Burner section volume, dm3 | 95 |
Combuster gate diameter, mm (+-3%) | 270 |
Flue system diameter, mm | 150 |
Flue system height, m, not less | 7 |
Wooden logs length, mm, not more |
650 |
Heated area volume limit, m3 | 100 |
Height, mm, not more | 770 |
Width, mm, not more | 650 |
Length, mm, not more | 1125 |
Weight, kg, not more | 170 |
Heat production limit, kW, not less |
25 |
Normal heat release, kW, +-15% |
11,0 |
Performance efficiency limit, %, not less | 75 |
Burner section volume, dm3 | 135 |
Combuster gate diameter, mm (+-3%) | 320 |
Flue system diameter, mm | 150 |
Flue system height, m, not less | 7 |
Wooden logs length, mm, not more |
800 |
Height, mm, not more | 890 |
Width, mm, not more | 546 |
Length, mm, not more | 414 |
Weight, kg, not more | 95 |
Heat production limit, kW, not less |
7,5 |
Performance efficiency limit, %, not less | 70 |
Fuel consumption limit kg/h, not more | 2,7 |
Flue system diameter, mm | 150 |
Minimal distance allowed to inflammable materials, cm aside behind In front |
40 35 80 |
Height, mm, not more | 870 |
Width, mm, not more | 475 |
Length, mm, not more | 415 |
Weight, kg, not more | 70 |
Heat production limit, kW, not less |
9 |
Performance efficiency limit, %, not less | 75 |
Flue system diameter, mm | 150 |
Minimal distance allowed to inflammable materials, cm aside behind |
40 35 |
Height, mm, not more | 835 |
Width, mm, not more | 475 |
Length, mm, not more | 490 |
Weight, kg, not more | 80 |
Heat production limit, kW, not less |
9 |
Performance efficiency limit, %, not less | 75 |
Fuel consumption limit kg/h, not more | 2,7 |
Flue system diameter, mm | 150 |
Minimal distance allowed to inflammable materials, cm aside behind In front |
40 35 80 |
Height, mm, not more | 1046 |
Width, mm, not more | 550 |
Length, mm, not more | 430 |
Weight, kg, not more | 105 |
Heat production limit, kW, not less |
9 |
Performance efficiency limit, %, not less | 75 |
Fuel consumption limit kg/h, not more | 2,7 |
Flue system diameter, mm | 150 |
Minimal distance allowed to inflammable materials, cm aside behind In front |
40 35 80 |
Height, mm, not more | 1133 |
Width, mm, not more | 495 |
Length, mm, not more | 419 |
Weight, kg, not more | 92 |
Heat production limit, kW, not less |
9 |
Performance efficiency limit, %, not less | 75 |
Fuel consumption limit kg/h, not more | 2,7 |
Flue system diameter, mm | 150 |
Minimal distance allowed to inflammable materials, cm aside behind In front |
40 35 80 |
Height, mm, not more | 957 |
Width, mm, not more | 560 |
Length, mm, not more | 407 |
Weight, kg, not more | 100 |
Heat production limit, kW, not less |
9 |
Performance efficiency limit, %, not less | 75 |
Fuel consumption limit kg/h, not more | 2,7 |
Flue system diameter, mm | 150 |
Minimal distance allowed to inflammable materials, cm aside behind In front |
40 35 80 |
Height, mm, not more | 832 |
Width, mm, not more | 560 |
Length, mm, not more | 407 |
Weight, kg, not more | 86 |
Heat production limit, kW, not less |
9 |
Performance efficiency limit, %, not less | 75 |
Fuel consumption limit kg/h, not more | 2,7 |
Flue system diameter, mm | 150 |
Minimal distance allowed to inflammable materials, cm aside behind In front |
40 35 80 |
Height, mm, not more | 920 |
Width, mm, not more | 595 |
Length, mm, not more | 430 |
Weight, kg, not more | 125 |
Heat production limit, kW, not less |
9 |
Performance efficiency limit, %, not less | 75 |
Fuel consumption limit kg/h, not more | 2,7 |
Flue system diameter, mm | 150 |
Minimal distance allowed to inflammable materials, cm aside behind In front |
40 35 80 |
Height, mm, not more | 920 |
Width, mm, not more | 595 |
Length, mm, not more | 495 |
Weight, kg, not more | 125 |
Heat production limit, kW, not less |
9 |
Performance efficiency limit, %, not less | 75 |
Fuel consumption limit kg/h, not more | 2,7 |
Flue system diameter, mm | 150 |
Minimal distance allowed to inflammable materials, cm aside behind In front |
40 35 80 |
Height, mm, not more | 873 |
Width, mm, not more | 854 |
Length, mm, not more | 430 |
Weight, kg, not more | 156 |
Heat production limit, kW, not less |
11 |
Performance efficiency limit, %, not less | 75 |
Fuel consumption limit kg/h, not more | 2,7 |
Flue system diameter, mm | 150 |
Minimal distance allowed to inflammable materials, cm aside behind In front |
40 35 80 |
Height, mm, not more | 873 |
Width, mm, not more | 854 |
Length, mm, not more | 495 |
Weight, kg, not more | 157 |
Heat production limit, kW, not less |
11 |
Performance efficiency limit, %, not less | 75 |
Fuel consumption limit kg/h, not more | 2,7 |
Flue system diameter, mm | 150 |
Minimal distance allowed to inflammable materials, cm aside behind In front |
40 35 80 |
You can use the following fuels:
TIME-TESTED HEATERS!
Forced air heater, also called as Buleryan Stove or Breneran, is used for air heating of residential, domestic, manufacturing, building under construction, warehouses, laboratories, greenhouses and other premises..
“Alaska” forced-air heaters are represented by metal constructions with welded tubes inside, which cause air convection and warm the room.
The heaters are based on gasification process which includes destructive distillation of wood and reheating that occurs as a result of hydrogen and marsh gas smoldering with the help of atomizer burner.
Are used for air heating of residential, domestic, manufacturing, buildings under construction, warehouses, laboratories, greenhouses and also for cooking (“Comfort-C”).
1 – door lock;
2 – door;
3 – lower air consumption controller;
4 – upper air consumption controller;
5 – ash storage bin;
6 – fire grate bar;
7 – fire-resistant brick;
8 – portable baffling;
9 – flue system;
10 – cooking top;
11 – safety cover;
12 – Heat-resistant glass.
(Heaters support information)
Detailed information on construction
and exploitation of "Alaska"Download
1. Alaska heater consrtuction
2. Guidence for use
3. Warranty
Detailed information on construction
and exploitation of"Comfort" chimney heater. Download
1. «Comfort» chimney heater consrtuction
2. Guidence for use
3. Warranty
Detailed information on construction
and exploitation of "Comfort-С" chimney heater. Download
1. «Comfort-С» chimney heater consrtuction
2. Guidence for use
3. Warranty
Detailed information on construction
and exploitation of "Lux" chimney heater. Download
1. «LUX» chimney heater consrtuction
2. Guidence for use
3. Warranty
Our happy customers recommend “Alaska” heaters
Just request additional info on «Alaska» heater or chimney heater «Comfort» and you'll get a detailed consultation: